RE-THINK INSULATION

Our products

ThermoWhite® insulation systems at a glance

The CE-certified ThermoWhite® loose-fill insulation balances out pipe runs seamlessly and reduces impact sound by up to 32 dB. Thanks to PLC-controlled MixMobil technology, 150-meter hose routing, and the "Speed Up" component, the highly load-bearing floor build-up is ready for covering after just 12 to 24 hours.

Why is ThermoWhite® loose-fill insulation ideal for floor construction? The CE-certified ThermoWhite® WD series eliminates thermal and sound bridges completely. The seamless insulation system adapts precisely to complex pipe layouts and variable installation heights on the structural slab.

Compared directly with conventional board systems, the loose-fill solution offers guaranteed impact sound improvement of up to 32 dB. It is suitable as a base for every application, from attic floors to pool backfills.

How does the MixMobil principle accelerate construction sites? The PLC-controlled MixMobil system guarantees absolute recipe consistency of WD products directly on site. Clean hose routing allows the material to be pumped flexibly over distances of up to 150 meters.

By adding the "Speed Up" component, the insulation system is ready for covering after 12 to 24 hours. The system provides architects, planners, and screed installers with high execution quality while drastically reducing setup times.

View Product Overview

Product categories at a glance

Select a category to highlight the matching area directly on the building model.

ThermoWhite® building model showing the product category application areas

Move your cursor over the building areas or use the category list to switch.

Complete Product Overview

ThermoWhite® WD 70 R (R/N) Premium

CE certification for ThermoWhite® WD 70 R (R/N) Premium
  • Lambda = 0.0381 W/mK
  • Traffic loads up to 10 kN/m²
  • Compressive stress CS(10)50 => 50 kPa
  • Only for thermal and impact sound insulation; not suitable for flat roofs and pool backfill.

ThermoWhite® WD 70 R (R/N)

CE certification for ThermoWhite® WD 70 R (R/N)
  • Uses pure recycled granulate
  • Very good thermal and impact sound insulation
  • Lambda = 0.045 W/mK
  • Traffic loads up to 16 kN/m²
  • Impact sound improvement up to 25 dB

ThermoWhite® WD 100 R

CE certification for ThermoWhite® WD 100 R
  • Uses pure recycled granulate
  • Very good thermal insulation
  • Lambda = 0.046 W/mK
  • Traffic loads up to 10 kN/m²
  • Excellent impact sound improvement

ThermoWhite® WD 130 R

CE certification for ThermoWhite® WD 130 R
  • Uses pure recycled granulate
  • Good thermal insulation
  • Lambda = 0.055 W/mK
  • Traffic loads up to 20 kN/m²
  • Excellent compressive strength
  • Compressive stress CS(10)100 = 100 kPa

ThermoWhite® WD 170 R A2

CE certification for ThermoWhite® WD 170 R A2
  • Non-combustible (A2-s1, d0)
  • Good thermal and impact sound insulation
  • Lambda = 0.077 W/mK
  • Traffic loads up to 20 kN/m²
  • Compressive stress CS(10)120 = min. 120 kPa

Product matrix

Technical characteristics of the ThermoWhite® WD products published on the WordPress product page.

Product matrix
FeatureUnitWD 70 R (R/N) PREMIUMWD 70 R (R/N)WD 100 RWD 130 RWD 170 R A2WD 50 R
Product type–Thermal and impact sound insulationThermal and impact sound insulationThermal and impact sound insulationThermal insulation (higher loads)Thermal insulation (high loads)Blown-in insulation
Thermal conductivity (λ), declared value (λR)W/mK0.0381 / 0.0400.045 / 0.0470.0464 / 0.0480.0550 / 0.0570.073 / 0.0770.040 / NPD
Reaction to fire–E––B-S1A2-s1, d0E
Dry densitykg/m³708811014523053
Compressive stress CS(10)kPa≥ 50≥ 50≥ 90≥ 100≥ 120NPD
Impact sound improvement (ΔLw)dB25252525NPDNPD
Maximum imposed loadkN/m²1016101920–
Water vapour diffusion resistance μ–4.56667.15

Notes and special features:

  • WD 70 R PREMIUM: Best thermal insulation value (0.0381 W/mK)

  • WD 170 R A2: Non-combustible (A2-s1, d0). Highest load-bearing capacity (20 kN/m²)

  • WD 50 R: Designed specifically as blown-in insulation. Lowest density and not suitable for foot traffic.

Additional information:

  • SpeedUp: ThermoWhite® SpeedUp can be used with all products to reduce drying times

  • Load: Matrix values are based on an installation thickness of 10 cm; higher maximum values shown on product cards apply to other installation thicknesses.

  • NPD: No Performance Determined

The advantages of the ThermoWhite® system

The ThermoWhite® system delivers tested insulation performance, sustainable materials, and quality made in Austria.

Certificates & verified quality

ThermoWhite® products comply with strict European quality standards.

The documents describe the tested system properties. We will clarify which evidence and installation conditions apply to your project in Denmark.

Evidence for your project in Denmark

Product version, system assembly and application conditions belong together. We help you identify the relevant documents.

Product-specific evidence

ETAs, declarations of performance and data sheets apply to the documented product version and installation conditions.

Controlled installation

The appropriate mixture, installation thickness and subsequent layers form part of the planned system assembly.

Danish environmental declaration

EPD MD-23094-DA_rev1 documents WD70, WD100 and WD130. Revised 5 April 2024, with stated validity until 29 September 2028.

Does every document apply to every product?

No. Product identity, version and installation conditions must match the document. The Danish EPD is not a blanket approval of the entire catalogue.

Which values apply to my floor assembly?

The appropriate current product version, planned thickness and complete system assembly determine the applicable values. Differences in older documents require technical clarification before any commitment.

Is funding guaranteed?

There is no blanket funding commitment. Market-specific and project-specific requirements must be checked separately.

Read the Danish EPD (Danish)

Certified Quality

Certified Quality

ThermoWhite® products meet strict European quality standards and are certified for the highest requirements.

ÖNORM EN 13163CE markingETA approval